Process analytics

Process analytics

Gas analyzers

Our analyzers monitor the O2/CO2 concentration in a wide variety of areas, whether in welding and soldering technology, the semiconductor, pharmaceutical or food industry, they are used wherever precise monitoring is required.
Through years of experience with a wide variety of customer needs and wishes, we have designed our analyzers to be flexible for many purposes and are constantly developing them further.
Equipped with intuitive menu navigation, all important parameters can be set and changed within a very short time.

Gas analyzers

Our analyzers monitor the O2/CO2 concentration in a wide variety of areas, whether in welding and soldering technology, the semiconductor, pharmaceutical or food industry, they are used wherever precise monitoring is required.
Through years of experience with a wide variety of customer needs and wishes, we have designed our analyzers to be flexible for many purposes and are constantly developing them further.
Equipped with intuitive menu navigation, all important parameters can be set and changed within a very short time.

Advantages

  • 30 years of experience, development and optimization
  • Top response time, short heat-up phase
  • Two different sizes for added flexibility
  • Durable components
  • Measurement data logging at different time intervals, output via RJ45/USB
  • Timer for filter change freely programmable
  • 5.7 inch display, intuitive operation
  • Indication of all alarms and errors on the display
  • Start measurements with external signal
  • Simple menu navigation in several languages Different RS232 protocols that can be changed                                    in the unit for communication with various Soldering,
  • packaging machines, analysers or other equipment and processes
  • Operation for user and administrator in different levels
  • Standardised 0/2-5/10 or 04-20 mA analogue signal
  • 3 backups for storing different device functions/settings
  • Barcode scanner optionally possible

Advantages

  • 30 years of experience, development and optimization
  • Top response time, short heat-up phase
  • Two different sizes for added flexibility
  • Durable components
  • Measurement data logging at different time intervals, output via RJ45/USB
  • Timer for filter change freely programmable
  • 5.7 inch display, intuitive operation
  • Indication of all alarms and errors on the display
  • Start measurements with external signal
  • Simple menu navigation in several languages Different RS232 protocols that can be changed in the unit for communication with various Soldering,
  • packaging machines, analysers or other equipment and processes
  • Operation for user and administrator in different levels
  • Standardised 0/2-5/10 or 04-20 mA analogue signal
  • 3 backups for storing different device functions/settings
  • Barcode scanner optionally possible 

Standard Versions

Zr-Ox EPC

…is the basic model and is used for continuous measurement of oxygen or O2/CO2 concentrations in gas mixtures.

Zr-Ox EPC Spot

…is our table-top device that can be used for random sample measurement of products that are packaged industrially or also for checking individual special packages.

Zr-Ox EPC VM

…is an analyser that is used, for example, in packaging machines to continuously measure and control the oxygen or O2/CO2 concentrations in the process. Furthermore, it is possible to carry out a random sample measurement with a separate sampling to ensure additional safety.

Custom-made products

Zr-Ox EPC 3GAS

…is a more flexible modification of the basic model. The device changes the measurement automatically or externally controlled in order to monitor several processes simultaneously.

Zr-Ox EPC SMC

…is equipped with an integrated proportional valve to control the gas supply directly without an external signal or valve.

Zr-Ox EPC EXS

…is a version with an external sensor that can be installed directly in the system to minimise relative measurement errors.

Other

A fast version with a high total flow (for closed-loop systems) is also available on request.
Or if you want to measure in overpressure from 0.2 -10 bar, as well as in the high temperature range from 200°C-1200°C.
  • More Product Pictures
  • Zr-Ox EPC Spot
  • Date sheet Zr-Ox EPC
 Zr-Ox EPC SMC                    Zr-Ox EPC 3Gas                     Zr-Ox EPC EXS
General Product data sheet
Sensor type:
Zirconium oxide (ceramic sensor)
Measuring range:
1 ppm- 100.00 % O2
0 % - 100 % CO2
Operating temperatur:
appr. 800 °C
Heating time:
appr. 5 min., ideally after 15 min.
Calibration:
5 calibration gases + air
Calibrate:
all 12 months with 5 calibration gases + air
Response time / sensor:
ca. 35 msec.
Response time / analyzer:
20.9 % - 0.01% in ca. 10 sec
Accuracy:
+/- 3% of the display from 100% - 1% O2
+/- 3% of the display from 100% - 20% CO2
+/- 5% of the display from 1% - 0.01% O2
+/- 5% of the display from 20% - 0% CO2
Flow sensor:
Flow measurement: 
65 ml/min + 12 seconds
Differential pressure sensor
                                                                                                                                                                                                                        
User interface:                         
5.7'' Touch display(145 mm)
Options and interface:
WEB interface for data communication
WEB interface for continuous data storage
Continuous data storage in the analyzer Indication of alarms on the display + acoustic signals
Menu navigation in several languages
Data export via LAN
Wi-Fi, RFID and barcode readers
Interface for USB, LAN, Micro USB, flow alarm, concentration alarm, system ready, USB pressure   
Error detection / system error:
Analyzer temperature, defective sensors, defective cables  
Alarms:
2x concentration alarms, 1x system alarm, flow alarm. all 3 alarms freely configurable
Relay load capacity:
max. 230 VAC, 3A
Analog outputs:
2x 0/4 - 20 mA or 0 - 10 VDC, free programmable
Power supply:
100-240 VAC / 47-63Hz
Line intake:
20 W in operation/ 35 W in the heating time
Housing:
Stainless steel housing in ½ 19 inch design
Housing dimensions:
Height 190 mm
Width 235 mm
Depth 355 mm
Weight:
Appr. 6 kg
Ambient temperatures:
Operation:        10-50 ºC (ohne Lüfter)
Storage:            +5-50 ºC
Humidity:
Operation:             95% non condensing
Storage:         <75% RH absolute humidity
Errors due to technical changes reserved.
General product data sheet
Sensor type:   
 
Zirconium oxide (ceramic sensor)
Measuring range: 
 
1 ppm – 100,00 % O2
Operating temperatur:
Heating time:
 
appr. 800 °C
5 min., ideally after 15 min.
Accuracy (12 months):
 
<3% of the target value for the measuring range from 1000 ppm - 20.9% <5% of the target value below 1000 ppm
Calibration
 
recommended every 12 months with at least 2 calibration gases
Response time / sensor:: 
 
ca. 35 msec.
Ansprechzeit/Analysator:
 
20,9 % - 10 ppm in < 1 minute
Flow rate:
Flow measuremen:
 
9 liters / min or 45 liters / min (EPC / EPC fast)
Differential pressure sensor
Housing:
 
Aluminum housing in ½- 19-inch design 4 height units, fastening straps
Housing dimensions:
 
Height 180/190 mm without / with device feet
Width 235/270 mm rear wall / front panel
Depth 355/395 mm without / with handles
Display:
 
5.7'' Touch display (145 mm)
Interfaces:
 
1 x RS 232 for data output, Ethernet
3 x alarm relays, freely configurable
Power supply:
 
100-240 VAC / 47-63Hz
Power consumption: 
 
25 W in continuous operation
35 W in heating time
Ambient temperatures:
During operation:
Storage:
During operation:
Storage:
 
 
0-50 degrees C (without fan)
+ 5-50 degrees C
95% RH non-condensing
<75% RH
 
 
Errors due to technical changes reserved.
  • More Product Pictures
  • Zr-Ox EPC Spot
  • Date sheet Zr-Ox EPC
 Zr-Ox EPC SMC
Zr-Ox EPC 3Gas
Zr-Ox EPC EXS
General Product data sheet
Sensor type:
Zirconium oxide (ceramic sensor)
Measuring range:
1 ppm- 100.00 % O2
0 % - 100 % CO2
Operating temperatur:
appr. 800 °C
Heating time:
appr. 5 min., ideally after 15 min.
Calibration:
5 calibration gases + air
Calibrate:
all 12 months with 5 calibration gases + air
Response time / sensor:
ca. 35 msec.
Response time / analyzer:
20.9 % - 0.01% in ca. 10 sec
Accuracy:
+/- 3% of the display from 100% - 1% O2
+/- 3% of the display from 100% - 20% CO2
+/- 5% of the display from 1% - 0.01% O2
+/- 5% of the display from 20% - 0% CO2
Flow sensor:
Flow measurement: 
65 ml/min + 12 seconds
Differential pressure sensor
                                                                                                                                                                                                                        
User interface:                         
5.7'' Touch display(145 mm)
Options and interface:
WEB interface for data communication
WEB interface for continuous data storage
Continuous data storage in the analyzer Indication of alarms on the display + acoustic signals
Menu navigation in several languages
Data export via LAN
Wi-Fi, RFID and barcode readers
Interface for USB, LAN, Micro USB, flow alarm, concentration alarm, system ready, USB pressure   
Error detection / system error:
Analyzer temperature, defective sensors, defective cables  
Alarms:
2x concentration alarms, 1x system alarm, flow alarm. all 3 alarms freely configurable
Relay load capacity:
max. 230 VAC, 3A
Analog outputs:
2x 0/4 - 20 mA or 0 - 10 VDC, free programmable
Power supply:
100-240 VAC / 47-63Hz
Line intake:
20 W in operation/ 35 W in the heating time
Housing:
Stainless steel housing in ½ 19 inch design
Housing dimensions:
Height 190 mm
Width 235 mm
Depth 355 mm
Weight:
Appr. 6 kg
Ambient temperatures:
Operation:        10-50 ºC (ohne Lüfter)
Storage:            +5-50 ºC
Humidity:
Operation:             95% non condensing
Storage:         <75% RH absolute humidity
Errors due to technical changes reserved.
General product data sheet
Sensor type:   
 
Zirconium oxide (ceramic sensor)
Measuring range: 
 
1 ppm – 100,00 % O2
Operating temperatur:
Heating time:
 
appr. 800 °C
5 min., ideally after 15 min.
Accuracy (12 months):
 
<3% of the target value for the measuring range from 1000 ppm - 20.9% <5% of the target value below 1000 ppm
Calibration
 
recommended every 12 months with at least 2 calibration gases
Response time / sensor:: 
 
ca. 35 msec.
Ansprechzeit/Analysator:
 
20,9 % - 10 ppm in < 1 minute
Flow rate:
Flow measuremen:
 
9 liters / min or 45 liters / min (EPC / EPC fast)
Differential pressure sensor
Housing:
 
Aluminum housing in ½- 19-inch design 4 height units, fastening straps
Housing dimensions:
 
Height 180/190 mm without / with device feet
Width 235/270 mm rear wall / front panel
Depth 355/395 mm without / with handles
Display:
 
5.7'' Touch display (145 mm)
Interfaces:
 
1 x RS 232 for data output, Ethernet
3 x alarm relays, freely configurable
Power supply:
 
100-240 VAC / 47-63Hz
Power consumption: 
 
25 W in continuous operation
35 W in heating time
Ambient temperatures:
During operation:
Storage:
During operation:
Storage:
 
 
0-50 degrees C (without fan)
+ 5-50 degrees C
95% RH non-condensing
<75% RH
 
 
Errors due to technical changes reserved.